Page 185 | 1.2 Operating by Using Machine and Device Handles GN 331 Tubular Handles with Electrical Switching Function continued Characteristics of the standard executions GN 331 The tubular handles have the CE marking, low voltage guideline 2014 / 35 / EU Emergency stop 2 channel, normally closed contact 1st button with 2 LED Changeover contact LED, red and green 2nd button Normally open contact Contact termination, Pin configuration Plug M12x1, 12-pole Switching voltage / Switching current max. 24 V DC / max. 0,5 A Operating voltage (LEDs) 24 V DC ±15% / 10 mA Protection class IP 67 (in screwed condition) Button color For each button a set of caps is included, in this colors: red, green, blue Additional variations as special application Emergency stop 1 channel Number of buttons > 2 Button optional with Normally open contact Normally closed contact Changeover contact Button with labelling area