Standard_Parts_Catalogue
Page 1582 | 3.5 Controlling, Venting, Sealing of Liquids and Gases GN 848 Float Switches for Level Monitoring 1 d 1 2 l 1 3 Type How to order 1 2 3 GN848-55-235-B 3 Type A With thread B With clamping flange 1 2 d 1 l 1 d 2 d 3 d 4 l 2 For level ≈ Type A Type B Standard langth for l max. Type A Type B l 3 min. l 4 max. 45 55 235 G 3 ⁄ 4 26,5 (G 3 ⁄ 4 ) 23 50 75 250 45 55 360 G 1 33,5 (G 1) 30 60 85 360 Float switches GN 848 can be used to monitor fluid levels by activating an electrical switching contact as soon as a defined filling level is exceeded or falls below a defined mark. The desired level at which the switching point is to be reached is determi- ned by the length of the float rod. With the float removed, this rod can be shortened; a scale for oil or water facilitates determining the exact length. The top end of the float rod features a magnet which activates a reed contact when the appropriate position is reached, irrespective of the me- dium to be monitored. Depending on the installation position of the magnet in the float rod, either normally open (NO) or normally closed (NC) may be operated. When delivered, the magnet is set for operating normally open (NO). Information • Housing, Float, Float rod Plastic (Polyamide PA) - - Temperature resistant up to 80 °C - - Gray Seal - - O-ring NBR (Perbunan ® ) (Type A) - - Flat sealing TPE (Type B) • Socket cap screws DIN 912 Steel, zinc plated • IP Protection Classes → Page 2153 • Plastic Characteristics → Page 2158 • RoHS Specification • Float switch with longer float rod On request Original design HFLT-E