Standard_Parts_Catalogue

Page 1565 | 3.5 Controlling, Venting, Sealing of Liquids and Gases 3.1 3.2 3.3 3.4 3.5 3.6 3.7 3.8 3.9 GN 650 / GN 650.1 Oil Level Indicators continued Assembly instruction The assembly of the oil level indicators GN 650 / GN 650.1 is very easy and economical. You need two drillings Ø 10,5 and/or Ø 12,5 mm in the distance l 1 in the container wall. The oil level indicator can also be ins- talled directly i.e. without nut, if the container wall has a fitting thread. All individual parts necessary for the assembly are provided: set screws with the drillings for oil, hexagon nuts, O-rings and serrated lock washers for safe guard. For perfect sealing by the O-rings the screws should not be too strongly tightened (max. 12 Nm). Recommended roughness of the sealing surface R A = 3 μm. Oil level indicators GN 650 Oil level indicators GN 650.1 Oil level indicators GN 650.2 (with Protective Housing) → Page 1566

RkJQdWJsaXNoZXIy MTQ2MTM=