Page 1519 | 3.4 Installing, Lifting, Damping with Leveling Feet, Lifting Gear and Rubber Elements 3.1 3.2 3.3 3.4 3.5 3.6 3.7 3.8 3.9 GN 589 Lifting Points continued Welding must be made by an approved welder in accordance with EN 287-1. The specified loading values are valid for an operating temperature of between –40 °C and +200 °C. Load capacities under higher temperatures provided on request. The operating instruction contains further guidelines and is included with every lifting point (see also at www.ganternorm.com/ en/service). Lifting point Size fillet seam Length Volume in cm 3 b = 100 ( 1,6 t) a = 4 251  4,016 137 ( 3,2 t) 6 344 12,38 172 ( 5,0 t) 7 431 21,10 228 (10,0 t) 8 576 36,86 Safety instructions The above details specify the maximum load in metric tonnes. Carefully check the wear markings for the abrasion of the lifting point. Use permitted No traces of wear Use not permitted Criteria reached: Material worn down to the wear marks Method of mounting Number Angles of inclination Factor 1 0° 1 1 90° 1 2 0° 2 2 90° 2 2 0 to 45° 1,4 2 45 to 60° 1 2 asymm. 1 3 and 4 0 to 45° 2,1 3 and 4 45 to 60° 1,5 3 and 4 asymm. 1 100  1,6 t 1,6 t  3,2 t  3,2 t  2,2 t 1,6 t 1,6 t 3,4 t 2,4 t 1,6 t 137  3,2 t 3,2 t  6,4 t  6,4 t  4,5 t 3,2 t 3,2 t 6,8 t 4,8 t 3,2 t 172  5,0 t 5,0 t  10,0 t  10,0 t  7,1 t 5,0 t 5,0 t 10,6 t 7,5 t 5,0 t 228  10,0 t 10,0 t  20,0 t  20,0 t  14,1 t 10,0 t 10,0 t 21,2 t 15,0 t 10,0 t