Page 1401 | 3.3 Hinging, Latching, Locking of Doors and Covers Mechanical features Maximum load Information with safety factor Examples of calculation → see operating instruction Load direction F A F R0 F R90 l 1 = 49 1500 N 1000 N 1000 N l 1 = 79  750 N  500 N  500 N Fixing from the back, 7 x threads M5, 6 mm deep Recommended torque 5 Nm (Screws M5) Protection class IP67 / IP69K (Mind the cable conduit!) acc. to EN 60529 Switching principle, contact opening Slow-action contacts force-fitted, with positive opening acc. to IEC 60947-5-1, K Contact material Silver alloy Operating travel diagram (scheme) The switching points are adjustable up to 4° in direction of 0°. see operating instruction Maximum operating frequency 600 operating cycles / hour acc. to IEC 60947-5-1, one operating cycle includes one opening and one closing action Mechanical life span 10 6 operating cycles Actuating speed min. 2° / second, max. 90° / second Electrical features / Safety features Utilization category AC 15: 24 V AC / 2A / DC 13: 24 V DC / 2A (connector plug) AC 15: 250 V AC / 4A / DC 13: 250 V DC / 0,3 A (cable) acc. to EN 60947-5-1 Contacts, termination 8-pole connector M12 or cable with 2 m or 5 m length Pin and cable assignment Type of cable Typ N 7x0,5 mm 2 , jacket PVC H05VV-F acc. to IEC 60332-1-2 et seqq. Short-circuit current 1000 A acc. to EN 60947-5-1 Rated insulation voltage 30 V AC / 36 V DC (connector plug) / 250 V AC (cable) Short-circuit protection 2 A, 500 V, Typ gG (connector plug) / 6 A, 500 V, Typ gG (cable) Ambient temperature - 25 °C up to + 80 °C Degree of pollution, external 3 acc. to EN 60947-5-1 Mission time (T M ) 20 years acc. to EN ISO 13849-1 Number of cycles (B10 d) 5 000 000 acc. to EN 61820-2 Approvals, Conformities, Applicability Low-voltage switchgear and controlgear CE declaration IMQ: CA02.03746 UL: E 131787 EN 60947-1/2007 EN 60947-1-5 : 2004 + A1/2009 Safety applications up to SIL 3 / PL e acc. to EN ISO 13849-1 GN 139.1 / 139.2 Hinges with Safety Switch continued Other important details and hints are given in the operating instruction for GN 139.1 hinges which are included with every hinge and which are also available as PDF downloads from „www.ganternorm.com “ under ‚Service‘. The hinges with safety switch must be mounted and commissioned by qualified technical personnel in compliance with the details given in the operating instructions and with the national and international rules and regulations and the applicable standards. Otto Ganter GmbH & Co. KG will assume no statutory liability for missing or incorrect information and for any consequences arising therefrom. 180° 0° 7° 9° NC NO 11°

RkJQdWJsaXNoZXIy MTQ2MTM=