Diaphragm_Pressure_Cylinders

Design: Housing: Al-alloy spray painted. Guide bushing with self-lubrication. Piston rod rotating. Piston rod made of stainless steel. MH 100 / 250 / 500 A Medium-stroke device type MH 100 A Weight 1.3 kg Single-acting Max. pressurisation = 10 bar Max. stroke = 50 mm Air consumption per stroke/6 bar = 0.1– 0.6 l Max. strokefrequency = 100/min. (at effective valve cross section of 50 mm ² ) Ambient temperature = -20 °C – +80 °C Medium-stroke device type MH 250 A Weight 3.4 kg Single-acting Max. pressurisation = 10 bar Max. stroke = 70 mm Air consumption per stroke/6 bar = 0.5– 2.5 l Max. strokefrequency = 75/min. (at effective valve cross section of 50 mm ² ) Ambient temperature = -20 °C – +80 °C A 2 L 9 L 8 L 7 A 1 D 1 D 5 12 Type A1 A2 D1 D2 D3 D4 D5 L1 L2 L3 L4 L5 L6 L7 L8 L9 L10 G1 G2 SW MH 100 A 78 78 80 32 70 12 6.5 124 92 24 12 4 11 110 95 8 16 M10 G 1/4 10 MH 250 A 115 115 118 42 105 20 9 158 120 33 17 4 14 160 140 12 21 M16 x 1.5 G 3/8 17 MH 500 A 145 145 150 55 135 20 9 248 206 60 24 5 14 196 170 15 21 M16 x 1.5 G 3/8 17 Dimensions Top view Side view Medium-stroke device type MH 500 A Weight 7.5 kg Single-acting Max. pressurisation = 10 bar Max. stroke = 110 mm Air consumption per stroke/6 bar = 1.0–7.0 l Max. strokefrequency = 18/min. (at effective valve cross section of 50 mm ² ) Ambient temperature = -20 °C – +80 °C Properties Type MH 100 A/B/C

RkJQdWJsaXNoZXIy MTQ2MTM=